[ASTPPCOM-419] Problem with failover trunks Created: 01/May/18 Updated: 12/Jul/18 Resolved: 12/Jul/18 |
|
| Status: | Done |
| Project: | ASTPP Community |
| Component/s: | None |
| Affects Version/s: | None |
| Fix Version/s: | None |
| Type: | Task | ||
| Reporter: | digidaz | Assignee: | Unassigned |
| Resolution: | Done | Votes: | 0 |
| Labels: | None | ||
| Remaining Estimate: | Not Specified | ||
| Time Spent: | Not Specified | ||
| Original Estimate: | Not Specified | ||
| Description |
|
When a trunk has failover configured, eg gateway1, gateway2, gateway3 I notice that if a call is rejected at the remote end and sends back a 486 busy then each of the failover gayeways is tried and the called party has to reject the call three times. |
| Comments |
| Comment by Samir Doshi [ 03/May/18 ] |
|
Yes, it will try as we have set continue_on_fail=true in code, that means in do failover for all not successful calls. You can either change code from call script or configure that parameter in gateway. Reference doc : https://wiki.freeswitch.org/wiki/Variable_continue_on_fail |
| Comment by (Community) DN (Inactive) [ 08/Jun/18 ] |
|
[~DigiDaz] |